Amalgam - A mixture of different elements.
Amalgamate - The forming of an amalgam; the
union of two materials; an alloy.
Ampere (A) - Unit of electrical current flow,
or rate of flow of electrons.
ANSI
386 - American National Standards instituted Standard for
high-voltage elbow connectors. Last issue date, 1985. Deadfront
arrest interfaces are defined in this standard.
ANSI/IEEE
C37.4 - Industry standards for fuses, air switches and
accessories.
ANSI/IEEE
C62-11 - American Nation Standards Institute Standard for
metal oxide surge arresters. Last issue date, 1993.
Arc
- Sparking that results when undesired current flows between two
point of differing potential.
Arc
Follower - An arc extinguishing extension on the end of an
ELS current-limiting fuse, an essential part of the EL Bay-O-Net
holder's loadbreak rating.
Arc
Strangler Loadbreaking Device - The arc strangler sleeve (red
cap) and cocking mechanism on a hinge-style mounted NX or NXII
current-limiting fuse that allows all current magnitudes from
excitation current through 200 amps to be interrupted positively
and safely by opening the fuse with a switchstick.
Arc
Strangler Switchblade - Switchblade with an arc strangler
loadbreaking device for hinged style mounting.
Arc
Voltage - The reaction of a circuit's inductance to the rate
of current change in the circuit; E = L(di/dt); when a
current-limiting fuse operates, there is an associated arc
voltage on the system.
Arrester - A protective
device for limiting surge voltages on equipment by diverting
surge current and returning the device to its original status. It
is capable of repeating these functions as specified.
Arrester,
Deadfront Type - An arrester assembled in a shielded housing
providing system insulation and conductive ground shield,
intended to be installed in an enclosure for the protection of
underground and padmounted distribution equipment and circuits.
Arrester,
Disconnect - A means for disconnecting an arrester after
failure in order to prevent a permanent fault on the circuit. It
also gives indication of a failed arrester.
Arrester,
Distribution, Heavy Duty Class - An arrester normally used to
protect overhead distribution systems exposed to severe lightning
currents.
Arrester,
Distribution, Light Duty Class - An arrester normally
installed on and used to protect underground distribution systems
where the major portion of the lightning stroke current is
discharged by an arrester located at the overhead line/cable
junction.
Arrester,
Distribution, Normal Duty Class - An arrester normally used
to protect overhead distribution systems exposed to typical
lightning currents.
Arrester,
Liquid-Immersed Type - An arrester designed for use immersed
in an insulating liquid.
Arrester,
Riser Pole Type - An arrester for pole mounting normally used
to protect underground distribution cable and equipment.
Arrester
Voltage Rating - RMS value of the maximum 60 Hz voltage to
which an arrester should be subjected, even under transient
conditions.
Arrestor
- See Arrester
Asymmetric
- A term used to explain the offset current waveform that can
occur when a fault is initiated; the composite quantity of the
transient current (dc component) and the steady state current (ac
component); usually considered to be 1.6 times the symmetric for
most electrical distribution systems.
ATZ
- Cooper Power Systems' station class, heavy duty, porcelain
housed arrester.
Aught
- Standard conductor size, i.e. 4 aught designation 4/0.
AWG
- American Wire Gauge: A conductor size designation, i.e., size
#2 through 4/0. (Refer to aught.)
AZF
- Cooper Power Systems' intermediate class, porcelain housed
arrester.
AZL
- Cooper Power Systems' distribution class, heavy duty, porcelain
housed arrester.
AZLP
- Cooper Power Systems' distribution class, heavy duty, polymer
housed arrester with 20 kA fault withstand rating.
AZR
- Cooper Power Systems' distribution class, heavy duty, riser
pole, porcelain housed arrester.
AZRP
- Cooper Power Systems' distribution class, heavy duty, riser
pole, polymer housed arrester with 20 kA fault withstand rating.
AZS
- Cooper Power Systems' distribution class, normal duty,
porcelain housed arrester.
AZSP
- Cooper Power Systems' distribution class, normal duty, polymer
housed arrester with 20 kA fault withstand rating.
AZU
- Cooper Power Systems' distribution class, heavy duty, under-oil
arrester.